• DocumentCode
    2213459
  • Title

    High Frequency Life Testing of Stator Coil Insulation

  • Author

    Manns, D. ; Galioto, S. ; Weeber, K. ; Yagielski, J.

  • Author_Institution
    GE Consumer & Ind., Large Motors & Generators, Peterborough, ON
  • fYear
    2008
  • fDate
    9-12 June 2008
  • Firstpage
    269
  • Lastpage
    272
  • Abstract
    This paper focuses on the development of insulation systems for high-speed and hence high-frequency electric motors with multi-MW ratings. With the growing demand for variable speed applications, an increasing number of medium and high voltage (4-13.8 kV) motors are being powered by adjustable speed drives (ASD´s). One aspect that must be understood during the design of the motor is the impact that the voltage waveform from the ASD may have on the stator insulation. Both high fundamental frequency components (300- 600 Hz), switching frequency components (low kHz range) and fast rise time transient voltages (in the mus range) from the ASD´s can increase the thermal and electrical stresses on the insulation resulting in a reduction of the service life. To study the effect of these ASD´s on an epoxy-mica based insulation system, accelerated life tests were performed at 60 Hz, 418 Hz and 10 KHz. The main purpose of this study was to determine if the number of ´electrical cycles´ to failure was constant for a given system over the range of voltages and frequencies tested and to explore if low frequency testing could be used as a predictor of insulation system life at higher frequencies. This paper will present the test setup and procedure, as well as the analysis and interpretation of the data. An examination of the resulting relationship between applied voltage, frequency and life of the insulation system will include a discussion of the ageing mechanisms at the various test voltages and frequencies.
  • Keywords
    ageing; coils; epoxy insulation; insulation testing; life testing; machine insulation; maintenance engineering; mica; stators; thermal stresses; variable speed drives; accelerated life tests; adjustable speed drives; ageing mechanisms; electrical stresses; epoxy-mica based insulation system; frequency 300 Hz to 600 Hz; frequency components; high frequency life testing; high-frequency electric motors; stator coil insulation; stator insulation; thermal stresses; voltage 4 kV to 13.8 kV; voltage waveform; Coils; Dielectrics and electrical insulation; Frequency; Insulation testing; Life testing; Stators; System testing; Thermal stresses; Variable speed drives; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, 2008. ISEI 2008. Conference Record of the 2008 IEEE International Symposium on
  • Conference_Location
    Vancouver, BC
  • ISSN
    1089-084X
  • Print_ISBN
    978-1-4244-2091-9
  • Electronic_ISBN
    1089-084X
  • Type

    conf

  • DOI
    10.1109/ELINSL.2008.4570326
  • Filename
    4570326