DocumentCode :
2218441
Title :
Modification of cathodic arc deposition profiles by magnetic multicusps
Author :
Anders, Simone ; MacGill, Robert A. ; Raoux, Sébastien ; Brown, Ian G.
Author_Institution :
California Univ., Berkeley, CA, USA
Volume :
2
fYear :
1996
fDate :
21-26 Jul 1996
Firstpage :
909
Abstract :
The deposition profile of a cathodic arc plasma source with and without magnetic macroparticle filter has been measured using a deposition probe technique. It has been found that the profile is close to a Gaussian and that the width of the profile depends on the cathode material. It was found that the dependence on the cathode material leads to a considerable radial variation of the elemental composition of the film when an alloy cathode is used. A magnetic multicusp field (magnetic bucket) near the exit of the plasma source or the magnetic filter was applied to flatten and homogenize the deposition profile
Keywords :
Gaussian distribution; magnetic field effects; plasma density; plasma deposited coatings; plasma deposition; plasma production; Ag; Al; Co; Fe; Gaussian profile; Pt; Ta; alloy cathode; cathodic arc deposition profiles modification; deposition probe technique; deposition profile homogenization; film elemental composition radial distribution; magnetic filter; magnetic macroparticle filter; magnetic multicusps; plasma source; plasma sources; Cathodes; Composite materials; Filters; Lead; Magnetic films; Magnetic materials; Magnetic separation; Plasma measurements; Plasma sources; Probes;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Discharges and Electrical Insulation in Vacuum, 1996. Proceedings. ISDEIV., XVIIth International Symposium on
Conference_Location :
Berkeley, CA
Print_ISBN :
0-7803-2906-6
Type :
conf
DOI :
10.1109/DEIV.1996.545496
Filename :
545496
Link To Document :
بازگشت