Abstract
This paper presents the design of an appropriate coupling interface circuit for measuring indoor power line transmission channel characteristics in CENELEC/FCC/ARIB low-frequency bands. This coupling circuit prevents the powerful and damaging 50 Hz/220 V current from entering sensitive measurement equipments while allowing narrowband PLC signals reception. It also guarantees impedance matching and instruments protection from very large voltage spikes and fast transients. Tests following EN 50065-2-3 standard [1] are done to verify that the proposed coupling interface provides a high safety level and is in compliance with immunity requirements.
Keywords
carrier transmission on power lines; impedance matching; safety; CENELEC/FCC/ARIB low-frequency bands; EN 50065-2-3 standard; coupling interface circuit design; fast transients; immunity requirements; impedance matching; indoor power line transmission channel characteristics; instruments protection; narrowband PLC signals reception; narrowband power line communication channel; safety level; sensitive measurement equipments; voltage spikes; Attenuation; Coupling circuits; Couplings; Frequency measurement; Narrowband; Power measurement; Transient analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC), 2012 IEEE International Symposium on
Conference_Location
Pittsburgh, PA
ISSN
2158-110X
Print_ISBN
978-1-4673-2061-0
Type
conf
DOI
10.1109/ISEMC.2012.6351760
Filename
6351760
Link To Document