Title :
Properties of the GSI HLI-RFQ structure
Author :
Friedrich, J. ; Schempp, A. ; Deitinghoff, H. ; Bessler, U. ; Klein, H. ; Veith, R. ; Angert, N. ; Klabunde, J.
Author_Institution :
Inst. fuer Angewandte Phys., J.W. Goethe Univ., Frankfurt, Germany
Abstract :
The ´High Charge State Injector (HLI)´ RFQ (radio frequency quadrupole) for the GSI accelerator facility was designed for acceleration of U/sup 28+/ from 2.5 to 300 keV/U. The structure has been built and tuned. Properties of the RFQ structure and first experimental results are presented.<>
Keywords :
ion accelerators; linear accelerators; 71.4 MeV; GSI HLI-RFQ structure; RFQ structure; U/sup 28+/; high charge state injector radiofrequency quadrupole; Acceleration; Couplings; Electrodes; Ion accelerators; Ion beams; Paramagnetic resonance; Physics; Space charge; Storage rings; Synchrotrons;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.165181