Title :
Tow tank testing and performance evaluation of a permanent magnet generator based small vertical axis hydrokinetic turbine
Author :
Khan, M.J. ; Iqbal, M.T. ; Quaicoe, J.E.
Author_Institution :
Powertech Labs. Inc., Surrey, BC, Canada
Abstract :
Vertical axis turbines using permanent magnet generators are being considered as options for use in hydrokinetic energy conversion. As a precursor to development of full-scale systems, scale-model turbines need to be tested in controlled environment. In this article, the results of tow tank testing of a small vertical axis turbine employing a permanent magnet generator are presented. Effects of rotor submersion, ripple propagation, and start-up behavior are presented along with relevant qualitative discussions. Results indicate an overall peak conversion efficiency of 22%. The critical limitations of these tests and general observations are also summarized at the end of this paper.
Keywords :
hydraulic turbines; hydrodynamics; hydroelectric generators; permanent magnet generators; testing; hydrokinetic energy conversion; permanent magnet generator; ripple propagation; rotor submersion; small vertical axis hydrokinetic turbine; start up behavior; tow tank testing; vertical axis turbine; Control systems; Energy conversion; Hydraulic turbines; Hydrodynamics; Permanent magnets; Renewable energy resources; Rotors; System performance; System testing; Wind turbines; Hydrokinetic Energy; Renewable Energy; Tow Tank TestingVertical Axis Turbine;
Conference_Titel :
Power Symposium, 2008. NAPS '08. 40th North American
Conference_Location :
Calgary, AB
Print_ISBN :
978-1-4244-4283-6
DOI :
10.1109/NAPS.2008.5307306