• DocumentCode
    2233917
  • Title

    Nonstationary methods and application to noisy ultrasound Doppler

  • Author

    Kouame, D. ; Girault, J.-M. ; Chemla, J.-P. ; Remeniera, J.-P. ; Lethiecq, M.

  • Author_Institution
    GIP Ultrasons Tours, LUSSI, Tours, France
  • fYear
    2002
  • fDate
    3-6 Sept. 2002
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Real time flow velocity measurement using ultrasound Doppler is a problem of considerable practical interest in industrial and biomedical applications. The principle consists in accessing flow velocity through estimation of Doppler spectrum or frequency. In presence of colored noise, the commonly used time frequency distributions and parametric Autoregressive methods become highly inaccurate. We propose in this paper to show via colored noisy Doppler simulation the suitability of modified parametric and parametric Wigner-ville techniques in this problem.
  • Keywords
    Doppler measurement; autoregressive processes; ultrasonic applications; velocity measurement; Doppler spectrum estimation; autoregressive method; colored noisy Doppler simulation; frequency estimation; noisy ultrasound Doppler; nonstationary method; parametric Wigner-ville technique; Doppler effect; Estimation; Frequency estimation; Noise measurement; Time-frequency analysis; Ultrasonic imaging; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Signal Processing Conference, 2002 11th European
  • Conference_Location
    Toulouse
  • ISSN
    2219-5491
  • Type

    conf

  • Filename
    7072002