Title :
On-line diagnosis of stator shorted turns in mains and inverter fed low voltage induction motors
Author :
Thomson, W.T. ; Morrison, D.
Author_Institution :
EM Diagnostics Ltd, UK
Abstract :
Motor current signature analysis (MCSA) is now widely used by industry to detect broken rotor bars and abnormal airgap eccentricity in a wide range of induction motors. The objective is to identify current components in the current signature pattern that are only a function of shorted turns and are not due to any other problem or mechanical drive characteristic. The results indicate that MCSA can diagnose shorted turns in mains and inverter fed induction motors.
Keywords :
DC-AC power convertors; fault diagnosis; induction motors; invertors; machine testing; rotors; short-circuit currents; stators; abnormal airgap eccentricity detection; broken rotor bars detection; current signature components identification; low-voltage induction motors; motor current signature analysis; online fault diagnosis; stator-shorted turns;
Conference_Titel :
Power Electronics, Machines and Drives, 2002. International Conference on (Conf. Publ. No. 487)
Print_ISBN :
0-85296-747-0
DOI :
10.1049/cp:20020100