DocumentCode
2236330
Title
On-line diagnosis of stator shorted turns in mains and inverter fed low voltage induction motors
Author
Thomson, W.T. ; Morrison, D.
Author_Institution
EM Diagnostics Ltd, UK
fYear
2002
fDate
4-7 June 2002
Firstpage
122
Lastpage
127
Abstract
Motor current signature analysis (MCSA) is now widely used by industry to detect broken rotor bars and abnormal airgap eccentricity in a wide range of induction motors. The objective is to identify current components in the current signature pattern that are only a function of shorted turns and are not due to any other problem or mechanical drive characteristic. The results indicate that MCSA can diagnose shorted turns in mains and inverter fed induction motors.
Keywords
DC-AC power convertors; fault diagnosis; induction motors; invertors; machine testing; rotors; short-circuit currents; stators; abnormal airgap eccentricity detection; broken rotor bars detection; current signature components identification; low-voltage induction motors; motor current signature analysis; online fault diagnosis; stator-shorted turns;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics, Machines and Drives, 2002. International Conference on (Conf. Publ. No. 487)
ISSN
0537-9989
Print_ISBN
0-85296-747-0
Type
conf
DOI
10.1049/cp:20020100
Filename
1031676
Link To Document