Title :
Notice of Retraction
Passive Islanding Detection Method for Grid Connected PV System
Author :
Fei Wang ; Zengqiang Mi
Author_Institution :
Key Lab. of Power Syst. Protection & Dynamic Security Monitoring & Control under Minist. of Educ., North China Electr. Power Univ., Baoding, China
Abstract :
Notice of Retraction
After careful and considered review of the content of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE´s Publication Principles.
We hereby retract the content of this paper. Reasonable effort should be made to remove all past references to this paper.
The presenting author of this paper has the option to appeal this decision by contacting TPII@ieee.org.
Passive islanding detection method is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition by monitor parameters in point of common coupling (PCC) such as voltage amplitude and frequency and then cause the inverter to shut down when there is sufficient transition from normal specified conditions. The real and reactive power equations and Non-Detection Zone (NDZ) of OVP/UVP and OFP/UFP methods for grid connected PV system are derived and analyzed in this paper. Analyses show that the behavior of the system at the time of disconnection will depend on the imbalance power at the instant before the switch opens to form the island, these results also indicate the NDZ of OVP/UVP and OFP/UFP methods is considerable large and the reaction times for these protective methodologies may be variable or unpredictable.
Keywords :
condition monitoring; distributed power generation; electrical safety; invertors; overvoltage protection; photovoltaic power systems; power generation protection; power grids; reactive power; basical inverter; condition monitor parameters; distributed generation; equipment safety; grid connected PV system; inverter; nondetection zone; overfrequency protection; overvoltage protection; personnel safety; photovoltaic power generation system; point-of-common coupling; reactive power equations; resident passive islanding detection method; underfrequency protection; undervoltage protection; Condition monitoring; Frequency; Inverters; Personnel; Photovoltaic systems; Power system protection; Safety devices; Solar power generation; Switches; Voltage; Distributed generation; grid connected; islanding detection method; photovoltaic system;
Conference_Titel :
Industrial and Information Systems, 2009. IIS '09. International Conference on
Conference_Location :
Haikou
Print_ISBN :
978-0-7695-3618-7
DOI :
10.1109/IIS.2009.83