DocumentCode
2243719
Title
Research and simulation of amplitude error and quadrature error for inductosyn
Author
Xianquan, Wang ; Min, Wu ; Ge, Zhu ; Jiqin, Feng
Author_Institution
Sch. of Electron. Inf. & Autom., Chongqing Univ. of Technol., Chongqing, China
Volume
2
fYear
2010
fDate
6-7 March 2010
Firstpage
354
Lastpage
357
Abstract
Two-phase amplitude and quadrature error of inductosyn have a great impact on the detection accuracy, through researching amplitude and quadrature error of inductosyn,eliminate its effects, and improve accuracy of inductosyn. First, analysis the characteristics of these two errors and their impact on the measurement accuracy. Then, research a new method, in the two position of 0° and 90°, respectively detecte their sine and cosine winding voltage , achieve amplitude and quadrature error detection, and amend their by using the software . Finally,experiments show that this new detection and correction method of error could improve the accuracy of Inductosyn.
Keywords
error correction; error detection; signal processing; amplitude error detection; cosine winding voltage; inductosyn; measurement accuracy; quadrature error detection; sine winding voltage; Analytical models; Asia; Automatic control; Computer errors; Error correction; Informatics; Robot control; Robotics and automation; Testing; Voltage; amplitude error; error compensation; inductosyn; quadrature error;
fLanguage
English
Publisher
ieee
Conference_Titel
Informatics in Control, Automation and Robotics (CAR), 2010 2nd International Asia Conference on
Conference_Location
Wuhan
ISSN
1948-3414
Print_ISBN
978-1-4244-5192-0
Electronic_ISBN
1948-3414
Type
conf
DOI
10.1109/CAR.2010.5456526
Filename
5456526
Link To Document