Title :
Reference curves of the pantograph impedance in DC railway systems
Author :
Ferravi, P. ; Maviscotti, A. ; Pozzobon, P.
Author_Institution :
Dept. of Electr. Eng., Genoa Univ., Italy
Abstract :
The spectrum of the conducted emissions of a locomotive drive is largely influenced by the electric behaviour of the supply net and by the interaction between the net itself and the on-board passive components (input filter). The main sources of variations of the impedance at the locomotive pantograph on a DC railway system are considered: substation filter, locomotive filter and locomotive position. A sensitivity analysis is performed to produce reference impedance curves
Keywords :
distribution networks; electric impedance; electric locomotives; pantographs; power overhead lines; sensitivity analysis; substations; traction; transmission line theory; DC railway systems; DC traction line; conducted emissions; input filter; locomotive drive; locomotive filter; locomotive pantograph; locomotive position; multiconductor transmission line model; onboard passive components; pantograph impedance; reference impedance curves; sensitivity analysis; substation filter; supply network; Conductors; Impedance; Partial differential equations; Passive filters; Rail transportation; Resonance; Resonant frequency; Sensitivity analysis; Substations; Voltage;