DocumentCode :
2246192
Title :
Attending small loads along a half-wavelength transmission line
Author :
Tavares, M.C. ; Torquato, R.
Author_Institution :
Sch. of Electr. & Comput. Eng., Univ. of Campinas (UNICAMP), Campinas, Brazil
fYear :
2011
fDate :
3-5 Oct. 2011
Firstpage :
255
Lastpage :
259
Abstract :
This paper presents some results on a Transmission Line a little greater than the Half-Wavelength (HWL+) attending small loads. A non-conventional 800 kV line with 2600 km with natural power of 4.8 GW was analyzed. The studies consisted in analyzing the capacity of this AC-Link feeding some small loads. The results confirm that this transmission is rather robust and can operate with small load drainage along its length.
Keywords :
power transmission lines; AC-link feeding; distance 2600 km; half-wavelength transmission line; load drainage; power 4.8 GW; voltage 800 kV; Cities and towns; Educational institutions; Peak to average power ratio; Power transmission lines; Reactive power; Steady-state; Voltage measurement; Long distance transmission line; half-wavelength; small loads feeding;