DocumentCode :
2246893
Title :
Interleaved switching topology for three-phase power-factor correction
Author :
Chunkag, V. ; Robinson, F.V.P.
Author_Institution :
Bath Univ., UK
fYear :
1994
fDate :
26-28 Oct 1994
Firstpage :
280
Lastpage :
285
Abstract :
Single-switch boost stages, connected between three-phase rectifiers and DC link capacitors, allow good power factor correction when operated in the discontinuous conduction mode. This paper is presented to aid design at all operating levels of this power converter type. For high output power, it is shown that reduced component stress and higher power factor results from the use of interleaved switching topologies. Some experimental results from a laboratory model are presented
Keywords :
DC-DC power convertors; circuit testing; network synthesis; network topology; power capacitors; power factor correction; rectifying circuits; switching circuits; DC link capacitors; component stress; design; discontinuous conduction mode; interleaved switching topologies; laboratory model; output power; power converter; power factor correction; rectifiers; single-switch boost stages; three-phase;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics and Variable-Speed Drives, 1994. Fifth International Conference on
Conference_Location :
London
Type :
conf
DOI :
10.1049/cp:19940978
Filename :
341569
Link To Document :
بازگشت