Abstract
The horizontal coupling plane (HCP) and the vertical coupling plane (VCP) are essential elements of the standardized electrostatic discharge (ESD) test. They are used for testing the robustness of equipment against indirect (nearby) discharges. This article analyzed the current and the fields on the HCP and the VCP using plane wave, transmission line, quasi-static theory. The objective is to illustrate the dominating physical processes on these planes. The work is based on measurements of the transient currents and fields using broadband sensors.
Keywords
approximation theory; charge measurement; electrostatic discharge; equivalent circuits; testing; transmission line theory; ESD currents; ESD fields; dominating physical processes; equipment robustness; horizontal coupling plane; plane wave theory; quasi-static approximations; standardized electrostatic discharge test; susceptibility; transmission line theory; vertical coupling plane; Calibration; Electromagnetic compatibility; Electromagnetic coupling; Electromagnetic modeling; Electrostatic discharge; IEC standards; Power system transients; Robustness; Testing; Transmission line theory;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2002. EMC 2002. IEEE International Symposium on
Conference_Location
Minneapolis, MN, USA
Print_ISBN
0-7803-7264-6
Type
conf
DOI
10.1109/ISEMC.2002.1032452
Filename
1032452
Link To Document