Title :
The 3 pi /4 backward TW structure for the ELETTRA 1.5 GeV electron injector
Author_Institution :
General Electric CGR MeV, Buc, France
Abstract :
The 3 pi /4 backward traveling wave structures used for the ELETTRA 1.5-GeV electron injector have been designed. The use of the 3 pi /4 accelerating mode is justified. After a description of the structure design, the choice of RF parameters leading to optimization with the RF pulse compressor and an evaluation of energy gain and peak field on copper based on simulations and cold test measurements are presented. RF cold test measurements of the first unit are analyzed.<>
Keywords :
cavity resonators; electron accelerators; linear accelerators; Cu; ELETTRA; RF parameters; RF pulse compressor; backward traveling wave structures; cold test measurements; electron injector; energy gain; linear accelerators; peak field; Acceleration; Copper; Design optimization; Electrons; Energy measurement; Gain measurement; Pulse compression methods; Pulse measurements; Radio frequency; Testing;
Conference_Titel :
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location :
San Francisco, CA, USA
Print_ISBN :
0-7803-0135-8
DOI :
10.1109/PAC.1991.165267