DocumentCode
2249712
Title
Maintain and validate radiated emissions measurements in a 10 meter semi-anechoic chamber
Author
Rose, Patrick ; Luvara, Michael
Author_Institution
Hewlett-Packard Co., Cupertino, CA, USA
Volume
1
fYear
2002
fDate
19-23 Aug. 2002
Firstpage
492
Abstract
In this paper, the authors describe the methods and procedures used to maintain and validate a 10 meter semi-anechoic chamber used for radiated emissions measurements. Included are a list of monthly, semi-annual, annual, and as needed checks and an approach for measurement software/hardware validation. Finally, they discuss a method by which to verify that a semi-anechoic chamber´s measurement system is really performing with accuracy in its measurements.
Keywords
anechoic chambers (electromagnetic); electromagnetic compatibility; electromagnetic interference; measurement errors; measurement systems; 10 m; EMC; EMI; measurement accuracy; measurement software/hardware validation; measurement system; radiated emissions measurements; semi-anechoic chamber; Antenna measurements; Brushes; Cables; Connectors; Gain measurement; Hardware; Inspection; Performance evaluation; Qualifications; Receiving antennas;