• DocumentCode
    2252088
  • Title

    Liquid handling using expandable microspheres

  • Author

    Griss, P. ; Andersson, Hakan ; Stemme, G.

  • Author_Institution
    Dept. of Signals, Sensors & Syst., R. Inst. of Technol., Stockholm, Sweden
  • fYear
    2002
  • fDate
    24-24 Jan. 2002
  • Firstpage
    117
  • Lastpage
    120
  • Abstract
    In this study we introduce two novel concepts for fluid handling in microfluidic systems and show their realization in micromachined test structures: a one-shot micropump and a normally open one-shot valve. Both principles use Expancel/spl reg/ microspheres, which are small spherical plastic particles that, when heated, increase their volume by a factor of about 60. The expansion is irreversible, i.e. when cooled again, the expandable microspheres do not shrink.
  • Keywords
    materials handling; microactuators; microfluidics; micropumps; microvalves; thermal expansion; Expancel microspheres; expandable microspheres; fluid handling; irreversible thermal expansion; microfluidic systems; micromachined test structures; normally open one-shot valve; one-shot micropump; one-shot unidirectional liquid actuator; small spherical plastic particles; Actuators; Hydrocarbons; Liquids; Microfluidics; Micropumps; Plastics; Pumps; Temperature distribution; Testing; Valves;