DocumentCode
2258369
Title
The Effect of Type of Transient Voltage Suppressor on the Signal Response of a Coupling Circuit for Power Line Communications
Author
Hove, M. ; Sanya, T.O. ; Snyders, A.J. ; Jandrell, I.R. ; Ferreira, H.C.
Author_Institution
Dept. of Electr. & Electron. Eng. Sci., Univ. of Johannesburg, Johannesburg, South Africa
fYear
2011
fDate
13-15 Sept. 2011
Firstpage
1
Lastpage
6
Abstract
The effect of the type of transient voltage suppressor (TVS) used in coupling circuits for surge protecting PLC equipment on the signal response has been studied. The study was focused at TVS devices used in both differential and common mode surge protection. It is found that the gas discharge tube (GDT) has no effect on the communication signal, whilst TVSs that operate on avalanche breakdown attenuate the signal and they also render signal dropout at a particular frequency. Metal Oxide Varistors (MOVs) behave similarly.
Keywords
carrier transmission on power lines; discharges (electric); surge protection; transients; varistors; common mode surge protection; coupling circuit; gas discharge tube; metal oxide varistors; power line communication; signal response; surge protecting PLC equipment; transient voltage suppressor; Attenuation; Bandwidth; Conferences; Coupling circuits; Distortion; Surge protection; Surges; MOVs; PLC; TVS; coupling circuit; surge protection; surge protection devices;
fLanguage
English
Publisher
ieee
Conference_Titel
AFRICON, 2011
Conference_Location
Livingstone
ISSN
2153-0025
Print_ISBN
978-1-61284-992-8
Type
conf
DOI
10.1109/AFRCON.2011.6072050
Filename
6072050
Link To Document