DocumentCode
2258551
Title
Implementation of a primary tapped transformer in a high frequency isolated power converter
Author
Joannou, A.J.L. ; Pentz, D.C.
Author_Institution
Group on Electron. Energy Process. (GEEP), Univ. Of Johannesburg, Johannesburg, South Africa
fYear
2011
fDate
13-15 Sept. 2011
Firstpage
1
Lastpage
6
Abstract
On load, transformer primary tap changing is not common in high frequency converters. This paper investigates a new converter topology to drive primary tapped transformers. The ideas that have been introduced previously are simply implemented into existing converter topologies which have been modified to accommodate a primary tapped transformer. The effects of efficiency with variation of source voltage and duty cycle are studied. It is shown that this topology can maintain a load voltage for a much wider source voltage variation without major sacrifices in efficiency.
Keywords
on load tap changers; power convertors; high frequency isolated power converter; load voltage; primary tapped transformer; source voltage variation; Frequency conversion; Power supplies; Switches; Topology; Voltage control; Voltage measurement; Windings; High frequency; power converters; primary tapped transformer; variable voltage source;
fLanguage
English
Publisher
ieee
Conference_Titel
AFRICON, 2011
Conference_Location
Livingstone
ISSN
2153-0025
Print_ISBN
978-1-61284-992-8
Type
conf
DOI
10.1109/AFRCON.2011.6072058
Filename
6072058
Link To Document