• DocumentCode
    2258551
  • Title

    Implementation of a primary tapped transformer in a high frequency isolated power converter

  • Author

    Joannou, A.J.L. ; Pentz, D.C.

  • Author_Institution
    Group on Electron. Energy Process. (GEEP), Univ. Of Johannesburg, Johannesburg, South Africa
  • fYear
    2011
  • fDate
    13-15 Sept. 2011
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    On load, transformer primary tap changing is not common in high frequency converters. This paper investigates a new converter topology to drive primary tapped transformers. The ideas that have been introduced previously are simply implemented into existing converter topologies which have been modified to accommodate a primary tapped transformer. The effects of efficiency with variation of source voltage and duty cycle are studied. It is shown that this topology can maintain a load voltage for a much wider source voltage variation without major sacrifices in efficiency.
  • Keywords
    on load tap changers; power convertors; high frequency isolated power converter; load voltage; primary tapped transformer; source voltage variation; Frequency conversion; Power supplies; Switches; Topology; Voltage control; Voltage measurement; Windings; High frequency; power converters; primary tapped transformer; variable voltage source;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    AFRICON, 2011
  • Conference_Location
    Livingstone
  • ISSN
    2153-0025
  • Print_ISBN
    978-1-61284-992-8
  • Type

    conf

  • DOI
    10.1109/AFRCON.2011.6072058
  • Filename
    6072058