DocumentCode
2258830
Title
Comment on "Selection of transformer cores for forward converters" - Paper #5.6 of APEC 1986 (Applied Power Electronics Conference)
Author
Watson, J.K.
Author_Institution
University of Florida Gainesville, Florida 32611
fDate
April 28 1986-1986
Firstpage
221
Lastpage
228
Abstract
The commentor provides an example that illustrates the use of the equations in the subject paper to do a preliminary design of a transformer for a forward converter. The assumed input voltage is 150 VDC, the output voltage is 12 VDC at 100 watts; the switching frequency is 40 khz. The core is chosen from the Ferroxcube family of EC cores using 3C8 ferrite material, for which catalog data are tabulated.
Keywords
Copper; Current density; Equations; Resistance; Transformer cores; Windings; Wires;