DocumentCode :
2263750
Title :
A fully digital self-calibration method for high resolution, pipelined A/D converters
Author :
Soenen, Eric G. ; Geiger, Randall L.
Author_Institution :
Mixed Signal Design Center, Texas Instrum. Inc., Dallas, TX, USA
fYear :
1993
fDate :
16-18 Aug 1993
Firstpage :
228
Abstract :
In highly accurate pipelined analog/digital converters, precise control of comparator trip-points, inter-stage amplifier gains and effective levels of reconstructing D/A converters is difficult. A new calibration approach allows errors on all these components, and compensates for them in the digital domain. A system identification technique using the converter itself, determines the required digital coefficients. The achievable accuracy is comparable to sigma-delta converters, at effective sampling rates almost two orders of magnitude higher
Keywords :
analogue-digital conversion; calibration; comparators (circuits); parallel architectures; pipeline processing; comparator trip-points; effective sampling rates; inter-stage amplifier gains; pipelined A/D converters; reconstructing D/A converters; self-calibration method; system identification technique; Analog-digital conversion; Calibration; Digital control; Equations; Instruments; Quantization; Signal design; Signal resolution; System identification; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Circuits and Systems, 1993., Proceedings of the 36th Midwest Symposium on
Conference_Location :
Detroit, MI
Print_ISBN :
0-7803-1760-2
Type :
conf
DOI :
10.1109/MWSCAS.1993.343088
Filename :
343088
Link To Document :
بازگشت