Stability analysis of V2 controlled buck converter operating in CCM and DCM
Author
Zhou, Guohua ; Xu, Jianping ; Jin, Yanyan ; Sha, Jin
Author_Institution
Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
fYear
2010
fDate
28-30 July 2010
Firstpage
551
Lastpage
555
Abstract
The operation principle of V2 controlled buck converter operating in continuous conduction mode (CCM) and discontinuous conduction mode (DCM) are analyzed. It is pointed out that V2 control is essentially a kind of control technique by utilizing peak output voltage as a control variable, quite similar to peak current-mode control. Stabilities of V2 controlled buck converter operating in CCM and DCM are analyzed in detail. It is concluded that V2 controlled buck converter is stable in CCM when duty ratio is less than 0.5 and in DCM for the whole range of duty ratio. When duty ratio is larger than 0.5, subharmonic oscillation of V2 controlled buck converter operating in CCM can be eliminated by using slope compensation. Simulation and experiment results are given to verify analysis results.
Keywords
current-mode circuits; power convertors; voltage control; CCM; DCM; buck converter; discontinuous conduction mode; peak current-mode control; peak output voltage; stability analysis; subharmonic oscillation; Converters; Inductors; Oscillators; Phase change materials; Switches; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Communications, Circuits and Systems (ICCCAS), 2010 International Conference on
Conference_Location
Chengdu
Print_ISBN
978-1-4244-8224-5
Type
conf
DOI
10.1109/ICCCAS.2010.5581936
Filename
5581936
Link To Document