DocumentCode :
2268631
Title :
A new technique for detection and location of arcing faults in power system apparatus
Author :
Sidhu, T.S. ; Singh, Gurdeep ; Sachdev, M.S.
Author_Institution :
Power Syst. Res. Group, Saskatchewan Univ., Saskatoon, Sask., Canada
Volume :
1
fYear :
1998
fDate :
24-28 May 1998
Firstpage :
185
Abstract :
A technique that detects an arcing fault in power apparatus is presented in this paper. It uses a PC based data acquisition system for detection of the arcing faults. It is shown that it is possible to determine its location in three dimensional space. The technique was implemented and tested in the laboratory. Some test results are also included in the paper. The proposed technique can be used to protect power system equipment, such as transformers, inductors, capacitors etc
Keywords :
arcs (electric); computerised instrumentation; data acquisition; fault location; power capacitors; power inductors; power transformer protection; PC based system; arcing faults detection; arcing faults location; capacitor protection; data acquisition; inductor protection; power system apparatus; power system equipment; three dimensional space; transformer protection; Capacitors; Data acquisition; Electrical fault detection; Fault detection; Inductors; Laboratories; Power system faults; Power system protection; Testing; Transformers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering, 1998. IEEE Canadian Conference on
Conference_Location :
Waterloo, Ont.
ISSN :
0840-7789
Print_ISBN :
0-7803-4314-X
Type :
conf
DOI :
10.1109/CCECE.1998.682713
Filename :
682713