Title
Electromagnetic performance analysis of 1.5MW doubly salient wind power generator
Author
Zhu, Jiaqi ; Ruan, Ligang ; Wang, Li
Author_Institution
Dept. of Electr. Eng., Nanjing Univ. of Aeronaut. & Astronaut., Nanjing, China
fYear
2011
fDate
20-23 Aug. 2011
Firstpage
1
Lastpage
5
Abstract
The advantages of doubly salient electromagnetic generator (DSEG) such as simple structure, high reliability, low cost and flexible control, reveals its application prospects in wind power generation system. To establish the two-dimensional model of DSEG, Ansoft Maxwell is used. On the basis, the steady-state and transient performances of megawatts DSEG are further discussed, including no-load characteristics, load characteristics and short-circuit characteristics. Simulation results indicate that megawatts DSEG has good operating performance.
Keywords
AC generators; reliability; wind power plants; Ansoft Maxwell; doubly salient wind power generator; electromagnetic performance analysis; flexible control; megawatts DSEG; power 1.5 MW; reliability; short-circuit characteristics; transient performances; two-dimensional model; Armature; Inductance; Rectifiers; Rotors; Stator windings; Windings;