DocumentCode :
2273368
Title :
Electromagnetic performance analysis of 1.5MW doubly salient wind power generator
Author :
Zhu, Jiaqi ; Ruan, Ligang ; Wang, Li
Author_Institution :
Dept. of Electr. Eng., Nanjing Univ. of Aeronaut. & Astronaut., Nanjing, China
fYear :
2011
fDate :
20-23 Aug. 2011
Firstpage :
1
Lastpage :
5
Abstract :
The advantages of doubly salient electromagnetic generator (DSEG) such as simple structure, high reliability, low cost and flexible control, reveals its application prospects in wind power generation system. To establish the two-dimensional model of DSEG, Ansoft Maxwell is used. On the basis, the steady-state and transient performances of megawatts DSEG are further discussed, including no-load characteristics, load characteristics and short-circuit characteristics. Simulation results indicate that megawatts DSEG has good operating performance.
Keywords :
AC generators; reliability; wind power plants; Ansoft Maxwell; doubly salient wind power generator; electromagnetic performance analysis; flexible control; megawatts DSEG; power 1.5 MW; reliability; short-circuit characteristics; transient performances; two-dimensional model; Armature; Inductance; Rectifiers; Rotors; Stator windings; Windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2011 International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4577-1044-5
Type :
conf
DOI :
10.1109/ICEMS.2011.6073455
Filename :
6073455
Link To Document :
بازگشت