DocumentCode :
2274237
Title :
Voltage Sensor Fault Detection and Reconfiguration for a Doubly Fed Induction Generator
Author :
Rothenhagen, Kai ; Thomsen, Sonke ; Fuchs, Friedrich W.
Author_Institution :
Kiel Univ., Kiel
fYear :
2007
fDate :
6-8 Sept. 2007
Firstpage :
377
Lastpage :
382
Abstract :
Fault detection and reconfiguration of the control loops of a Doubly-Fed Induction Generator are described in this paper. The stator voltage is measured as well as observed. During fault free operation, the measured signal is used for the field oriented control. In case of a voltage sensor fault, the faulty measurement is identified and the control is reconfigured using the observer output. Operation without measuring the stator voltage is possible. Laboratory measurements prove this concept.
Keywords :
asynchronous generators; fault diagnosis; machine vector control; sensors; stators; voltage measurement; control loop reconfiguration; doubly fed induction generator; field oriented control; stator voltage measurement; voltage sensor fault detection; Fault detection; Fault diagnosis; Induction generators; Inverters; Laboratories; Observers; State estimation; Stators; Voltage control; Voltage measurement; AC generators; Observers; State estimation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Diagnostics for Electric Machines, Power Electronics and Drives, 2007. SDEMPED 2007. IEEE International Symposium on
Conference_Location :
Cracow
Print_ISBN :
978-1-4244-1061-3
Electronic_ISBN :
978-1-4244-1062-0
Type :
conf
DOI :
10.1109/DEMPED.2007.4393123
Filename :
4393123
Link To Document :
بازگشت