Title :
Dc link inverter for army power conditioner requirements
Author :
Corry, Thomas M. ; McKechnie, Robert M. ; Williams, Robert A.
Author_Institution :
Delco Electron. Div., Gen. Motors Corp., Santa Barbara, CA, USA
Abstract :
This paper describes the 12.5 kVA dc link inverter being developed by Delco Electronics - Santa Barbara Operations for USA MERDC, Ft. Belvoir, Virginia. The inverter can produce 120/ 208 volts three-phase, 120 volts single-phase, or 120/240 volts single-phase power at 60 or 400 Hz. It has an efficiency of 84 to 94% and a breadboard weight of 150 pounds. Based on a patented design concept (No. 3,725,767), the inverter generates stepped wave and square wave voltage segments which are combined as a three-phase composite to produce line-to-line waveforms of 4% total harmonic content before filtering. Study results show that the basic inverter concept can take several circuit forms, and can be developed with ratings up to 100 kVA. The inverter is being developed as a candidate for the Army 15 kVA general purpose power conditioner, and as such must conform to MIL-STD-1332B and MIL-STD-461A.
Keywords :
harmonics; invertors; military equipment; square-wave generators; DC link inverter; Delco Electronics; MIL-STD-1332B; MIL-STD-461A; Santa barbara operation; USA MERDC; apparent power 12.5 kVA; apparent power 15 kVA; army power conditioner; line-to-line waveform; square wave generation; stepped wave generation; three-phase composite; Attenuators; Harmonic analysis; Inverters; Power harmonic filters; Thyristors; Windings;
Conference_Titel :
Power Electronics Specialists Conference, 1974 IEEE
Conference_Location :
Murray Hill, NJ
DOI :
10.1109/PESC.1974.7074362