DocumentCode :
2277365
Title :
A new approach to determine phase shift of shunt based on the sampling measurement and substitution method
Author :
Wang Lei ; Lu Zuliang ; Li Min ; Liu Lijuan ; Zhou Hao
Author_Institution :
Nat. Inst. of Metrol., Beijing
fYear :
2008
fDate :
8-13 June 2008
Firstpage :
202
Lastpage :
203
Abstract :
A new approach to determine phase-shift of shunt based on the sampling measurement and substitution method is described with theoretical analysis and test results. The differences with SP´s results are within 2 murad at fundamental wave of 50 Hz and within 30 murad at 30th harmonic.
Keywords :
phase shifters; sampling methods; frequency 50 Hz; phase shift; sampling measurement; substitution method; Electrical resistance measurement; Equivalent circuits; Instruments; Metrology; Parasitic capacitance; Phase measurement; Power measurement; Resistors; Sampling methods; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location :
Broomfield, CO
Print_ISBN :
978-1-4244-2399-6
Electronic_ISBN :
978-1-4244-2400-9
Type :
conf
DOI :
10.1109/CPEM.2008.4574723
Filename :
4574723
Link To Document :
بازگشت