Abstract
The precision measurement for harmonic current and power up to 60th order and some validating experiments is reported. The uncertainty of harmonics current reference to fundamental is less than 36 muA/A (k=2) for range up to 50 A. The uncertainty of harmonic power reference to the fundamental apparent power is less than 42 muW/VA (k=2) for voltage and current range up to 500 V and 50 A.
Keywords
electric current measurement; measurement standards; power measurement; harmonic current measurement; harmonic power measurement; harmonic power reference; harmonic power standard; harmonics current reference; industrial frequency; Circuit noise; Current measurement; Frequency measurement; Metrology; Power measurement; Power system harmonics; Signal design; Signal resolution; Uncertainty; Voltage;