Abstract
For calibration of analyzer of harmonic voltage, current and power under non-sinusoidal condition at fundamental in industrial frequency, a harmonic power standard has been built at NIM, in which non-integer-period sampling is applied. Its setup, algorithm, and whole uncertainty are reported.
Keywords
calibration; electric current measurement; measurement standards; power measurement; voltage measurement; NIM; National Institute of Metrology; calibration; compensation algorithm; harmonic current analyzer; harmonic power analyzer; harmonic power standard; harmonic voltage analyzer; industrial frequency; noninteger-period sampling; Algorithm design and analysis; Calibration; Clocks; Frequency; Harmonic analysis; Power system harmonics; Sampling methods; Standards development; Synchronization; Voltage;