• DocumentCode
    2277759
  • Title

    Simple switch open fault detection method of voltage source inverter

  • Author

    Jung, Shin-Myung ; Park, Jin-Sik ; Kim, Hyoung-Suk ; Kim, Hag-Wone ; Youn, Myung-Joong

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., KAIST, Daejeon, South Korea
  • fYear
    2009
  • fDate
    20-24 Sept. 2009
  • Firstpage
    3175
  • Lastpage
    3181
  • Abstract
    Recently, permanent magnet synchronous motors are applied to various applications such as electric vehicle, aerospace, medical service, and military applications due to several outstanding characteristics. Because of the importance of high reliable operation in these areas, many researches which are related to the fault detection and diagnosis of inverter systems are conducted. In this paper, a new simple fault detection method of voltage source inverter for permanent magnet synchronous motor is proposed. The feasibility of the proposed method is proved by simulation and experiment. By the simulation and experiments, rapid detection characteristic of the proposed method has been proved without any additional voltage sensor.
  • Keywords
    fault diagnosis; invertors; permanent magnet motors; synchronous motors; fault diagnosis; permanent magnet synchronous motors; switch open fault detection; voltage source inverter; FDD; fault detection; switch open fault; voltage source inverter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
  • Conference_Location
    San Jose, CA
  • Print_ISBN
    978-1-4244-2893-9
  • Electronic_ISBN
    978-1-4244-2893-9
  • Type

    conf

  • DOI
    10.1109/ECCE.2009.5316260
  • Filename
    5316260