DocumentCode
2278295
Title
High performance harmonic isolation by means of the single-phase series active filter employing the Waveform Reconstruction Method
Author
Senturk, Osman S. ; Hava, Ahmet M.
Author_Institution
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
fYear
2009
fDate
20-24 Sept. 2009
Firstpage
1451
Lastpage
1458
Abstract
This paper proposes the waveform reconstruction method (wrm), which is utilized in the single-phase series active filter´s (SAF´s) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line current sampling delay reduction method (SDRM), a single-phase SAF compensated system provides higher harmonic isolation performance and higher stability margins compared to the system using conventional synchronous reference frame based methods. The analytical, simulation, and experimental studies of a 2.5 kW single-phase SAF compensated system prove the theory.
Keywords
active filters; wavelet transforms; high performance harmonic isolation; load harmonic voltage component; power 2.5 kW; sampling delay reduction method; single-phase series active filter control algorithm; voltage harmonic type single-phase diode rectifier loads; waveform reconstruction method; Harmonic; harmonic extraction; isolation; power quality; rectifier; series active filter;
fLanguage
English
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
Conference_Location
San Jose, CA
Print_ISBN
978-1-4244-2893-9
Electronic_ISBN
978-1-4244-2893-9
Type
conf
DOI
10.1109/ECCE.2009.5316287
Filename
5316287
Link To Document