• DocumentCode
    2278684
  • Title

    Validation of inductance measurements at NMi VSL

  • Author

    Dierikx, E.F. ; van der Beek, J.H.N.

  • Author_Institution
    NMi Van Swinden Lab., Delft, Netherlands
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    338
  • Lastpage
    339
  • Abstract
    To validate an inductance resonance bridge, which is based on a commercial capacitance bridge, a second resonance bridge was built, based on a self-composed 4 terminal-pair impedance ratio bridge. From analysis of the results on 100 mH standards at 1 kHz, discrepancies have been resolved and the uncertainty has been improved to 26 muH/H.
  • Keywords
    bridge instruments; inductance measurement; measurement uncertainty; frequency 1 kHz; inductance measurements; inductance resonance bridge; self- composed 4 terminal-pair impedance ratio bridge; standards; uncertainty; Bridge circuits; Capacitance; Capacitors; Equations; Impedance; Inductance measurement; Inductors; RLC circuits; Resistors; Resonance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574791
  • Filename
    4574791