DocumentCode
2278903
Title
AC-DC current transfer difference in CMI
Author
Zachovalová, V. Nováková
Author_Institution
Dept. of DC & LF Electr. quantities, CMI, Czech Republic
fYear
2008
fDate
8-13 June 2008
Firstpage
362
Lastpage
363
Abstract
This paper describes AC-DC current transfer difference measurement system in CMI which is able to measure AC-DC current differences from 3 mA up to 10 A in the frequency range 10 Hz - 10 kHz.
Keywords
electric current measurement; measurement uncertainty; AC-DC current transfer difference measurement system; current 3 mA to 10 A; frequency 10 Hz to 10 kHz; uncertainty calculation; Current measurement; Electric variables measurement; Frequency measurement; Measurement standards; Power distribution; Power measurement; Switches; Testing; Time measurement; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location
Broomfield, CO
Print_ISBN
978-1-4244-2399-6
Electronic_ISBN
978-1-4244-2400-9
Type
conf
DOI
10.1109/CPEM.2008.4574803
Filename
4574803
Link To Document