• DocumentCode
    2279350
  • Title

    Design and evaluation of a WR-15 (50 to 75 GHz) microcalorimeter

  • Author

    Crowley, T.P. ; Cui, Xiaohai

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Boulder, CO
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    420
  • Lastpage
    421
  • Abstract
    The design and correction factor evaluation of a WR-15 (50 to 75 GHz) rectangular waveguide microcalorimeter is presented. This new microcalorimeter will be the US national standard for power from 50 to 75 GHz. It can measure the effective efficiency of a wider variety of transfer standards than can the previous microcalorimeter. It has also been designed so that its correction factor can be experimentally evaluated by multiple techniques.
  • Keywords
    calorimeters; rectangular waveguides; transfer standards; waveguide components; US national standard; correction factor evaluation; rectangular waveguide microcalorimeter; transfer standard; Fasteners; Flanges; Heat pumps; Measurement standards; NIST; Rectangular waveguides; Sensor systems; Thermal sensors; Thermistors; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574832
  • Filename
    4574832