• DocumentCode
    2279480
  • Title

    Single-phase PFC boost converter operating at instantaneous power interruption

  • Author

    Jappe, Tiago Kommers ; Mussa, Samir Ahmad

  • Author_Institution
    INEP-Power Electron. Inst., Fed. Univ. of Santa Catarina, Florianopolis, Brazil
  • fYear
    2009
  • fDate
    20-24 Sept. 2009
  • Firstpage
    2771
  • Lastpage
    2776
  • Abstract
    The voltage sags and instantaneous power interruptions are probably the most significant power quality problem facing industrial customers today. In switchmode power supplies, the CCM boost PFC converter, with average current mode control, is widely used as first-stage. However, at the instantaneous power interruption, the controllers go to saturate mode, consequently the switching device (MOSFET or IGBT) may damage permanently at power return after voltage interruption. Therefore, this paper verifies this problem and proposes a simple protection strategy to limit transitory current after power interruption. Simulation and experimental results confirm and validate the proposed control strategy.
  • Keywords
    electric current control; power convertors; power factor correction; power supply quality; power system protection; PFC boost converter; average current mode control; power factor correction; power supply quality; power system protection; switching device; switchmode power supply; voltage sags; Current control; Digital circuits; Digital control; Industrial power system transients; Overcurrent protection; Power electronics; Power factor correction; Power quality; Power system dynamic stability; Surge protection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition, 2009. ECCE 2009. IEEE
  • Conference_Location
    San Jose, CA
  • Print_ISBN
    978-1-4244-2893-9
  • Electronic_ISBN
    978-1-4244-2893-9
  • Type

    conf

  • DOI
    10.1109/ECCE.2009.5316354
  • Filename
    5316354