DocumentCode
2279632
Title
Application of counter Helmholtz’s coils in the magneto optical trap
Author
Su Duo-wu ; Ji Wang-xi
Author_Institution
Nat. Inst. of Metrol., Beijing
fYear
2008
fDate
8-13 June 2008
Firstpage
460
Lastpage
461
Abstract
In this paper, theoretical calculation to related parameter of the counter-Helmholtz´s coils is first processed, and experimentalized it later. It was found that time constant T is always fell short of destined target. Think over winding parameter and the correlative theoretical calculation is processed. Additionally, we improved experimental testing set. Here, the measured time constant is accorded with destined target, viz. T<1 ms.
Keywords
coils; windings; Helmholtz coils; magneto-optical trap; time constant; winding parameter; Atom lasers; Atom optics; Atomic beams; Chaos; Charge carrier processes; Coils; Counting circuits; Magnetic field measurement; Magnetic fields; Metrology;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location
Broomfield, CO
Print_ISBN
978-1-4244-2399-6
Electronic_ISBN
978-1-4244-2400-9
Type
conf
DOI
10.1109/CPEM.2008.4574852
Filename
4574852
Link To Document