Title :
Application of counter Helmholtz’s coils in the magneto optical trap
Author :
Su Duo-wu ; Ji Wang-xi
Author_Institution :
Nat. Inst. of Metrol., Beijing
Abstract :
In this paper, theoretical calculation to related parameter of the counter-Helmholtz´s coils is first processed, and experimentalized it later. It was found that time constant T is always fell short of destined target. Think over winding parameter and the correlative theoretical calculation is processed. Additionally, we improved experimental testing set. Here, the measured time constant is accorded with destined target, viz. T<1 ms.
Keywords :
coils; windings; Helmholtz coils; magneto-optical trap; time constant; winding parameter; Atom lasers; Atom optics; Atomic beams; Chaos; Charge carrier processes; Coils; Counting circuits; Magnetic field measurement; Magnetic fields; Metrology;
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location :
Broomfield, CO
Print_ISBN :
978-1-4244-2399-6
Electronic_ISBN :
978-1-4244-2400-9
DOI :
10.1109/CPEM.2008.4574852