• DocumentCode
    2280374
  • Title

    A Kelvin resistance bridge with the frequency range from dc to 100 kHz

  • Author

    Huang, L. ; Li, Z. ; Zhang, Z. ; Zhao, W.

  • Author_Institution
    Nat. Inst. of Metrol., Beijing
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    554
  • Lastpage
    555
  • Abstract
    For the accurate measurement and calibration of the famous Tinsley 5685 AC standard resistors, a new type of Kelvin resistance bridge working over frequency range from DC to 100 kHz is described. At the same time, a bridge substitution technique is used in which the unknown Tinsley resistor is compared to the standard of AC/DC calculable resistor with double helix arrangement. Through this bridge the frequency characteristics of these portable AC standard resistors with the resistance value from 1 Omega to 10 kOmega have been obtained, which will extend their frequency range in metrology calibration.
  • Keywords
    bridge circuits; calibration; electric resistance measurement; measurement standards; resistors; Kelvin resistance bridge; Tinsley 5685 AC standard resistors; calibration; frequency 100 kHz; resistance 1 kohm to 10 kohm; Arm; Battery charge measurement; Bridge circuits; Detectors; Electrical resistance measurement; Frequency measurement; Kelvin; Measurement standards; Metrology; Resistors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574899
  • Filename
    4574899