• DocumentCode
    2280508
  • Title

    Modified Maxwell-Wien bridge with auto source balance

  • Author

    Cheng, Ding ; Wenjun, Lu

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    568
  • Lastpage
    569
  • Abstract
    This paper describes the realization of auto source balance in a modified Maxwell-Wien bridge by using a differential amplifier. The method of eliminating the oscillation of this differential amplifier is also discussed. The inductance measurement error introduced by the adoption of differential amplifier and related compensation circuit has also been analyzed in details. In the range of 100 muH~100 H, the inductance measurement error caused by the amplifier is less than 2 ppm under 1 kHz .
  • Keywords
    bridge circuits; differential amplifiers; inductance measurement; measurement errors; auto source balance; compensation circuit; differential amplifier; frequency 1 kHz; inductance measurement error; modified Maxwell-Wien bridge; Bridge circuits; Capacitance; Capacitors; Differential amplifiers; Earth; Inductance measurement; Maxwell equations; Metrology; Satellite ground stations; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574906
  • Filename
    4574906