DocumentCode
2280629
Title
Direct 10 V Josephson Voltage Standard comparison between a programmable sinis array and a conventional sis array
Author
Djordjevic, S. ; Seron, O. ; Solve, S. ; Chayramy, R.
Author_Institution
Lab. Nat. de Metrol. et d´´Essais (LNE), Trappes
fYear
2008
fDate
8-13 June 2008
Firstpage
582
Lastpage
583
Abstract
In December 2007, a comparison of the 10 V Josephson Array Voltage Standard (JAVS) of the LNE was performed with that of the BIPM in the framework of BIPM.EM-KlO.b comparison. During the week allotted to the exercise, the measurement setup was optimized to achieve a relative voltage difference of 7times10-12 within a relative Type A uncertainty of 8times10-12. We then took the opportunity to carry out a direct comparison of a 10 V PTB programmable array against the LNE JAVS. We report on the experiments performed to establish the uncertainty budget. We present the characterization of a 10 V SINIS array. We conclude with the results of a direct comparison against the LNE JAVS.
Keywords
Josephson effect; measurement standards; measurement uncertainty; voltage measurement; BIPM; Josephson array voltage standard; LNE JAVS; PTB programmable array; SIS array; measurement uncertainty; optimized measurement setup; programmable SINIS array; relative type A uncertainty; relative voltage difference; voltage 10 V; Data acquisition; Detectors; Electrical resistance measurement; Frequency estimation; Measurement standards; Microwave frequencies; Sensor arrays; Stability; Uncertainty; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location
Broomfield, CO
Print_ISBN
978-1-4244-2399-6
Electronic_ISBN
978-1-4244-2400-9
Type
conf
DOI
10.1109/CPEM.2008.4574913
Filename
4574913
Link To Document