• DocumentCode
    2280671
  • Title

    Precise calibration on DC voltage

  • Author

    Xiuzeng, Zhang ; Lili, Zhang ; Honggang, Zhao ; Yue, Liu ; Benxia, Zou ; Jiangtao, Zhang

  • Author_Institution
    Div. of Electr. & Quantum Metrol., Nat. Inst. of Metrol., Beijing
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    588
  • Lastpage
    589
  • Abstract
    DC voltage was traced to DC voltage reference (FLUKE 732A) by the calibrated divider (datron 4902S). The divider supplied 18 fixed ratios to calibrate DC voltage from 10 mV to 1000 V. DC voltage traceability mainly depends on the DC voltage reference and DC voltage divider. The DCV reference is traced to JJAVS twice a year, with the uncertainty of 1 times 10-7 (k=l). After calibration, the uncertainty of DCV ratios can reach 1 times 10-7(k=l). As for daily calibration, the uncertainty of DC voltage depends on the long term stability of DCV ratios and the voltage effect of the ratios.
  • Keywords
    calibration; voltage dividers; DC voltage; FLUKE 732A; calibration; voltage 10 mV to 1000 V; voltage divider; voltage effect; Calibration; Electrical capacitance tomography; Laboratories; Leakage current; Low voltage; Metrology; Resistors; Stability; Temperature dependence; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574916
  • Filename
    4574916