  • Abstract
    NIST recently reported the first application of a quantum AC Josephson voltage standard (ACJVS) for calibration of thermal transfer standards in the 1 kHz to 10 kHz frequency range. This paper describes preliminary work on extending its frequency calibration range up to 100 kHz by correcting systematic errors due to voltage leads.
  • Keywords
    Josephson effect; measurement errors; superconducting junction devices; transfer standards; voltage measurement; ACJVS; NIST; frequency 1 kHz to 10 kHz; frequency calibration; quantum AC Josephson voltage standard; systematic error correction; thermal transfer standards; voltage leads; Calibration; Coaxial cables; Error correction; Frequency; Instruments; Josephson junctions; Low pass filters; NIST; Power harmonic filters; Voltage;