• DocumentCode
    2281634
  • Title

    An automatic measurement apparatus for low value magnetic flux with high resolution

  • Author

    He Qing

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    100
  • Lastpage
    101
  • Abstract
    When a low value flux is to be measured, the induced signal in the measuring coil would be very weak and the instrument resolution thus becomes very important (Chen Duoxingr, Magnetic field Measurement, Beijing, 1985). Here a nanovoltmeter is used as the preamplifier to detect the induced signal from the measuring coil and is followed by a digital integrator to obtain the flux value. Thus a resolution of less than 1 nWb for flux measurement is attained.
  • Keywords
    coils; electromagnetic induction; integrating circuits; magnetic flux; magnetic variables measurement; preamplifiers; signal resolution; voltmeters; automatic measurement apparatus; digital integrator; flux measurement resolution; induced signal; instrument resolution; low value magnetic flux measurement; measurement resolution; measuring coil; nanovoltmeter preamplifier; Coils; Computer errors; Current measurement; Force measurement; Magnetic field measurement; Magnetic flux; Preamplifiers; Signal resolution; Wire; Wounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034739
  • Filename
    1034739