DocumentCode
2282768
Title
Direct determination of capacitance standards using a quadrature bridge and a pair of quantised Hall resistors
Author
Inglis, A.D. ; Wood, B.M. ; Cote, M. ; Young, R.B. ; Early, M.D.
Author_Institution
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
fYear
2002
fDate
16-21 June 2002
Firstpage
242
Lastpage
243
Abstract
We describe measurements made using a quadrature bridge to simultaneously compare two quantum Hall resistors (QHRs) with two 10 nF capacitors at 1233 Hz. This direct approach eliminates uncertainties due to thermal and structural instabilities and to AC/DC differences of the wire resistors normally used with an AC ratio bridge as an intermediary stage.
Keywords
Hall effect devices; bridge circuits; capacitance measurement; capacitors; measurement standards; measurement uncertainty; quantum Hall effect; resistors; thermal stability; 10 nF; 1233 Hz; AC ratio bridge intermediary stage; QHR; capacitance standards; capacitors; quadrature bridge; quantised Hall resistor pair; quantum Hall resistors; structural instability uncertainties; thermal instability uncertainties; wire resistor AC/DC differences; Bridge circuits; Capacitance; Capacitors; Councils; Frequency; Laboratories; Magnetic field measurement; Measurement standards; Resistors; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location
Ottawa, Ontario, Canada
Print_ISBN
0-7803-7242-5
Type
conf
DOI
10.1109/CPEM.2002.1034812
Filename
1034812
Link To Document