• DocumentCode
    2282898
  • Title

    Development of a high precision AC standard shunt for AC power measurement

  • Author

    Tsuchiyama, T. ; Tadokoro, T.

  • Author_Institution
    Japan Electr. Meters Inspection Corp., Tokyo, Japan
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    254
  • Lastpage
    255
  • Abstract
    The authors developed an AC standard shunt (rated 10 A, 0.1 /spl Omega/), for frequencies from DC to 10 kHz, which has a highly stable resistance value and small phase angle error. By using this AC standard shunt, AC power and current may be measured with high accuracy. The stability and uncertainty of the shunt correspond to 3 ppm with regard to AC power measurement at 1 kHz.
  • Keywords
    circuit stability; electric current measurement; measurement errors; measurement standards; measurement uncertainty; power measurement; resistors; 0 Hz to 10 kHz; 0.1 ohm; 1 kHz; 10 A; AC current measurement accuracy; AC high precision standard shunts; AC power measurement; phase angle error; resistance value stability; resistance value uncertainty; resistors; shunt frequency measurement range; shunt rating; Capacitance; Circuit stability; Eddy currents; Inductance; Measurement standards; Power measurement; Printed circuits; Resistors; Standards development; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034818
  • Filename
    1034818