• DocumentCode
    2282956
  • Title

    Direct-reading absolute calibration of ac voltage ratio standards

  • Author

    Callegaro, L. ; Bosco, G.C. ; D´Elia, Vincenzo ; Serazio, D.

  • Author_Institution
    Electr. Metrol. Dept., Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    262
  • Lastpage
    263
  • Abstract
    A new system for ac voltage ratio absolute calibration has been developed at IEN. The voltage ratio is maintained with a new one-decade, two-stage inductive voltage divider. The setup for ratio self-calibration is based on the simplest possible application of the bootstrap method: during the step-up the voltage differences are directly read with a vector voltmeter having an extremely high ac common-mode rejection ratio (CMRR).
  • Keywords
    bootstrap circuits; calibration; measurement standards; voltage dividers; voltage measurement; voltmeters; AC voltage ratio standard; bootstrap method; common-mode rejection ratio; direct-reading absolute calibration; inductive voltage divider; self-calibration; vector voltmeter; Calibration; Metrology; Optical fibers; Optical reflection; Power transformer insulation; Stability; Time measurement; Voltage; Voltmeters; Wounds;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034822
  • Filename