• DocumentCode
    2283159
  • Title

    Calculable impulse voltage calibrator for calibration of impulse digitizers

  • Author

    Hallstrom, J. ; Chekurov, Y. ; Aro, M.

  • Author_Institution
    High Voltage Inst., Helsinki Univ. of Technol., Finland
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    286
  • Lastpage
    287
  • Abstract
    Design and construction of a calibrator for lightning and switching impulse voltage measuring instruments is presented. The operating voltage range is from 50 mV to 300 V. The estimated uncertainty for the peak value is 0.03% and for front time and time to half value less than 1%.
  • Keywords
    calibration; lightning; measurement standards; measurement uncertainty; switching transients; voltage measurement; 50 mV to 300 V; front time uncertainty; impulse digitizer calibration; impulse voltage calibrator; lightning impulse voltage measuring instruments; operating voltage range; peak value uncertainty; switching impulse voltage measuring instruments; time to half value uncertainty; Calibration; Capacitors; Equivalent circuits; Impedance; Impulse testing; Instruments; Lightning; Surges; Voltage; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034833
  • Filename
    1034833