DocumentCode :
2283754
Title :
Voltage and Pulse Endurance Test of New Generation wire CORONA-R developed by P. Leo - BCwire®
Author :
Choi, Wai Fung ; Cheng, Eric ; Wong, Peter
Author_Institution :
Dept. of Electr. Eng., Hong Kong Polytech. Univ., Kowloon
fYear :
2006
fDate :
12-14 Nov. 2006
Firstpage :
40
Lastpage :
44
Abstract :
Inverters are commonly used in varies motor application. This greatly increases the pulse endurance stress of the wire due to switching transience. A new type of wire with three layers of insulation material has been developed by BCwirereg to overcome aforementioned problem. Which this paper gives brief introduction of the wire, details test procedure, preliminary results with compared with traditional insulation wires which where commonly used nowadays. The aim of this paper is to let user have better understanding of this new type of wire and give enough information for wire selection.
Keywords :
insulated wires; CORONA-R wire; new generation wire; pulse endurance test; voltage endurance test; wire selection; Cable insulation; Conducting materials; Corona; Electronic equipment testing; Insulation testing; Power electronics; Pulse generation; Stress; Voltage; Wire;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Systems and Applications, 2006. ICPESA '06. 2nd International Conference on
Conference_Location :
Hong Kong
Print_ISBN :
962-367-544-5
Type :
conf
DOI :
10.1109/PESA.2006.343066
Filename :
4147779
Link To Document :
بازگشت