DocumentCode
2283893
Title
DC electrical accelerated ageing tests on polyethylene insulation
Author
Brown, M.A. ; Chen, G. ; Rogers, B.F. ; Davies, A.E. ; Rochester, C.
Author_Institution
Dept. of Electr. Eng., Southampton Univ., UK
fYear
1996
fDate
23-26 Sep 1996
Firstpage
281
Lastpage
284
Abstract
This paper reports on an on-going study into assessing the long term dc performance and reliability of moulded production joints used in submarine repeatered optic communication cable systems. Emphasis is being placed on using meaningful short term accelerated ageing tests, results of which can be extrapolated to service life and conditions. Electrical breakdown data from ramp and constant stress tests of production mouldings are presented along with thin film samples microtomed from various parts of mouldings. Bulk space charge measurements of aged samples are reported and their effect on failure data are discussed
Keywords
polyethylene insulation; DC electrical accelerated ageing test; electrical breakdown; failure; microtomed thin film; moulded production joint; polyethylene insulation; reliability; service life; space charge; submarine repeatered optic communication cable system;
fLanguage
English
Publisher
iet
Conference_Titel
Dielectric Materials, Measurements and Applications, Seventh International Conference on (Conf. Publ. No. 430)
Conference_Location
Bath
ISSN
0537-9989
Print_ISBN
0-85296-670-9
Type
conf
DOI
10.1049/cp:19961041
Filename
607400