DocumentCode :
2283901
Title :
A precision set-up and method for calibrating a DC voltage divider´s ratios from 10 V to 1000 V
Author :
Slinde, H. ; Lind, K.
Author_Institution :
Nat. Stand. Dept., Justervesenet, Kjeller, Norway
fYear :
2002
fDate :
16-21 June 2002
Firstpage :
372
Lastpage :
373
Abstract :
A precision set-up and method for calibrating the division ratios of a resistive divider for DC-voltage in the range 10 V to 1000 V is described. The method requires equipment commonly available in most standard laboratories. Uncertainties better than 3/spl times/10/sup -7/ (k = 2) in the ratio is achieved.
Keywords :
calibration; measurement standards; measurement uncertainty; voltage dividers; voltage measurement; 10 to 1000 V; DC voltage divider ratio precision calibration; calibration set-up/method; divider voltage range; measurement uncertainty; resistive divider division ratios; Calibration; Electrical resistance measurement; Instruments; Laboratories; Noise measurement; Optical filters; Optical noise; Uncertainty; Voltage; Voltmeters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
Type :
conf
DOI :
10.1109/CPEM.2002.1034877
Filename :
1034877
Link To Document :
بازگشت