• DocumentCode
    2283985
  • Title

    Voltage dividers with low phase angle errors for a wideband power measuring system

  • Author

    Rydler, K.-E. ; Svensson, S. ; Tarasso, V.

  • Author_Institution
    SP Swedish Nat. Testing & Res. Inst., Boras, Sweden
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    382
  • Lastpage
    383
  • Abstract
    A set of resistive voltage dividers has been designed for low phase angle errors. The dividers were made for a wideband power measuring systems to cover voltages up to 1000 V. The phase angle errors of the dividers have been verified in a step-up procedure using two sampling voltmeters. Except for the highest ranges the phase angle errors are within a few /spl mu/rad at 50 Hz and within /spl plusmn/ 50 /spl mu/rad at 1500 Hz.
  • Keywords
    measurement errors; measurement standards; power measurement; voltage dividers; voltmeters; 0 to 1000 V; 50 to 1500 Hz; phase angle errors; reference power measuring system; resistive voltage dividers; sampling voltmeters; step-up procedure; wideband power measuring system; Capacitance; Capacitors; Instruments; Low voltage; Phase measurement; Power measurement; Sampling methods; Transducers; Voltmeters; Wideband;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034882
  • Filename
    1034882