• DocumentCode
    2284517
  • Title

    Delay calibration method for precise and accurate two way satellite time and frequency transfer

  • Author

    Imae, M. ; Aida, M. ; Gotoh, T. ; Shibuya, Y. ; Kurihara, N.

  • Author_Institution
    Commun. Res. Lab., Tokyo, Japan
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    450
  • Lastpage
    451
  • Abstract
    The two way satellite time and frequency transfer (TWSTFT) is one of the most accurate and precise time transfer techniques. But there are possibilities of nanosecond level time transfer errors due to delay variations, mainly caused by temperature variations. This paper reports a measurement technique under development at the Communications Research Laboratory using a multi-channel time transfer modem.
  • Keywords
    calibration; delays; frequency measurement; measurement errors; modems; satellite communication; thermal stability; time measurement; transfer standards; TWSTFT time transfer technique; delay calibration method; earth station delays; multi-channel time transfer modems; precise/accurate two-way satellite time/frequency transfer; temperature variation generated delay variations; time transfer errors; Antenna measurements; Artificial satellites; Calibration; Delay effects; Demodulation; Frequency; Low-noise amplifiers; Modems; Satellite ground stations; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034916
  • Filename
    1034916